Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Implant Dent Relat Res ; 17(2): 402-11, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23742098

RESUMO

BACKGROUND: Typically, dental implants are placed in irradiated bone after a delay that exceeds 6 months, but it is not known whether longer delays are beneficial. PURPOSE: The purpose of the study is to review the literature comparing the failure rate of dental implants placed in irradiated bone between 6 and 12 months and after 12 months from the cessation of radiotherapy. MATERIALS AND METHODS: Four electronic databases were searched for articles published until February 2013 without language restriction: Lilacs, Medline, Scopus, and the Cochrane Central Register of Controlled Trials. Two reviewers independently assessed the eligibility criteria and extracted data. Fixed effect meta-analysis was performed. RESULTS: Overall, 3,749 observational studies were identified. After the screening of titles and abstracts, 236 publications were selected, and 10 were included in the final analysis. The pooled relative risk (RR) of failure was RRpooled = 1.34 (95% confidence interval [CI]: 1.01-1.79), higher in individuals who had dental implants installed between 6 and 12 months after receiving radiotherapy. I(2) indicated nearly 21% heterogeneity (p = .25). Egger's test indicated no evidence of publication bias (p = .62); however, the removal of one study significantly affected the overall RR (RRpooled = 1.08, 95% CI: 0.77-1.52). CONCLUSIONS: Placing implants in bone within a period shorter than 12 months after radiotherapy may result in a higher risk of failure; however, additional evidence from clinical trials is needed to verify this risk.


Assuntos
Processo Alveolar/efeitos da radiação , Processo Alveolar/cirurgia , Implantação Dentária Endóssea , Implantes Dentários , Falha de Restauração Dentária , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos
2.
J Oral Implantol ; 39(5): 533-8, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21534821

RESUMO

The present study measured removal torque and bone-implant interface resistance of machined implants, acid-etched implants, or machined implants irradiated around the implant area with infrared low-level laser therapy (LLLT; 830 nm) immediately after surgery. There were statistically significant differences between Groups A (control) and B (rough surface) (P = .03). Implants with a rough surface seem to add resistance to the bone-implant interface compared with smooth titanium implants or implants treated with LLLT.


Assuntos
Implantes Dentários , Remoção de Dispositivo , Osseointegração/efeitos da radiação , Análise de Variância , Animais , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Fêmur , Terapia com Luz de Baixa Intensidade , Ratos , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos da radiação , Torque
3.
J Craniofac Surg ; 23(2): 613-5, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22446431

RESUMO

Facial gunshot wounds pose a challenge for head and neck surgeons as it is usually accompanied by significant soft and bone tissue loss and impairment of the stomatognathic system. This article reports the case of a patient who had sustained facial gunshot wound and had the projectile lodged at the upper disk space of the right-side temporomandibular joint, which caused mandible function impairment and pain. The projectile was surgically removed via endaural access, and the patient was later submitted to physiotherapy. After treatment, the function of the joint was reestablished, the pain disappeared, and the aesthetics results were considered excellent, with no sequels. The surgical removal of the projectile of the temporomandibular joint combined with the postsurgical physiotherapy showed to be an efficient treatment to the present case.


Assuntos
Corpos Estranhos/cirurgia , Articulação Temporomandibular/lesões , Articulação Temporomandibular/cirurgia , Ferimentos por Arma de Fogo/cirurgia , Adolescente , Feminino , Corpos Estranhos/diagnóstico por imagem , Humanos , Intubação Intratraqueal , Articulação Temporomandibular/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ferimentos por Arma de Fogo/diagnóstico por imagem
4.
J Craniofac Surg ; 23(1): 145-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22337393

RESUMO

Treatment of facial trauma sequelae is a complex and challenging process. There is still controversy over suitable materials for orbital wall reconstruction. This study evaluated calcium phosphate cement (CPC) implants manufactured by rapid prototyping in the repair of orbital wall defects secondary to trauma. Computed tomographic scans of 5 patients were used for surgery planning and production of CPC implants. Implants were used to restore orbital wall anatomy, ocular alignment, and facial contour. Benefits resulting from the use of implants, such as a reduced operating time, patient response to biomaterial implantation, biomaterial integrity and stability, and patient satisfaction with treatment, were analyzed qualitatively. Our results suggest that CPC is an effective and safe material for orbital reconstruction because of its biocompatibility and easy production and placement.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Substitutos Ósseos/uso terapêutico , Fosfatos de Cálcio/uso terapêutico , Órbita/cirurgia , Fraturas Orbitárias/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Próteses e Implantes , Adulto , Materiais Biocompatíveis/química , Substitutos Ósseos/química , Fosfatos de Cálcio/química , Sulfato de Cálcio/química , Desenho Assistido por Computador , Diplopia/cirurgia , Enoftalmia/cirurgia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Transtornos da Motilidade Ocular/cirurgia , Doenças Orbitárias/cirurgia , Planejamento de Assistência ao Paciente , Segurança do Paciente , Satisfação do Paciente , Fosfatos/química , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Tomografia Computadorizada Espiral , Resultado do Tratamento
5.
Acta Cir Bras ; 26(1): 2-6, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21271196

RESUMO

PURPOSE: To evaluate new bone formation, by the analysis of optical density, in rat femoral defects filled with calcium phosphate cement (CPC) and bioactive glass (BG). METHODS: Twenty-one rats were divided into three groups, Group I (CPC), Group II (BG), and Group III (control), and assessed after 7, 15, and 30 days. Three bone cavities were made in the left femur and filled with CPC, BG, and no material (control). Digital images were obtained and the results were subjected to statistical analysis of variance (ANOVA), complemented by the Friedman and Kruskal-Wallis nonparametric tests, with a significance level of 5%. RESULTS: Regarding optical density, Group I showed statistical values significantly higher than Group III and also higher, although not statistically significant, than Group II, in all observation periods. When Groups II and III were compared, Group II showed higher optical density values, without statistically significant differences, in all periods. CONCLUSION: The biomaterials analyzed showed higher optical density in relation to the control group in all observation periods, calcium phosphate cement being the best option in the repair of bone defects, but without statistically significant differences in relation to bioactive glass.


Assuntos
Cimentos Ósseos/uso terapêutico , Regeneração Óssea/fisiologia , Substitutos Ósseos/uso terapêutico , Fosfatos de Cálcio/uso terapêutico , Fêmur/lesões , Vidro , Animais , Cimentos Ósseos/química , Densidade Óssea , Substitutos Ósseos/química , Fosfatos de Cálcio/química , Fêmur/diagnóstico por imagem , Vidro/química , Masculino , Radiografia , Distribuição Aleatória , Ratos , Ratos Wistar , Estatísticas não Paramétricas
6.
J Dent Child (Chic) ; 77(2): 111-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20819408

RESUMO

This case report describes the treatment of a patient with an unerupted maxillary left central incisor, class III malocclusion with crossbite of the maxillary posterior teeth and lateral open bite. Treatment consisted of rapid maxillary expansion followed by anterior space opening, maxillary protraction and traction of the unerupted teeth with a light force system. Favorable results were obtained in terms of correcting incisor position and class III malocclusion. The results achieved remained stable throughout a 4-year retention period.


Assuntos
Incisivo/patologia , Má Oclusão Classe III de Angle/terapia , Ortodontia Corretiva/métodos , Dente Impactado/terapia , Cefalometria , Criança , Aparelhos de Tração Extrabucal , Feminino , Seguimentos , Humanos , Mordida Aberta/terapia , Extrusão Ortodôntica/instrumentação , Técnica de Expansão Palatina/instrumentação , Planejamento de Assistência ao Paciente , Técnicas de Movimentação Dentária/instrumentação , Técnicas de Movimentação Dentária/métodos , Dente não Erupcionado/terapia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...